Helkama Bica Marine and Offshore Cables EN

Tel. +358 2 410 8700 , fax +358 2 237 2428 , helkamabica.com Subject to change without prior notice. See latest updates on our webpage. 16 10/2017 LKAM-HF Screened power and control cable 0,6/1kV DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-360 3. Screen - drain wire of tinned copper 1,0mm 2 (in all sizes) - aluminium polyester tape, coverage 100% IEC 60092-350 4. Rip cord - rip cord for conductors from 16mm 2 5. Sheath - polyolefine plastic, SHF1 IEC 60092-360 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request Application: For fixed installation in most areas and on open deck in ships and offshore units, especially when lightweight and screened cables are needed. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-404 conditions according to 60092-360/SHF2 Temperature rating: Maximum conductor temperature + 90 °C Fixed installation - 40 °C to +80 °C Minimum recommended installation temperature - 15 °C For details see general information section ● Flame-retardant ● Halogen-free ● Low smoke emission ● Oil resistant (only SHF2)